We have successfully constructed and tested a pair of high-field coils that is part of the magnet set of the Mirror Fusion Test Facility (MFTF-B) at the Lawrence Livermore National Laboratory. Each coil consists of a multifilamentary Nb3Sn magnet nested inside a multifilamentary NbTi magnet. During our test, these coils produced a central field of 12 T, with a peak conductor field of 12.5 T. The dimensions of the Nb3Sn insert coil are: 0.36-m bore, 1.32-m outer diameter, and 1.14-m overall length. These coils were designed to be fully cryogenically stabilized and cooled by pool-boiling liquid helium. The operating current density of the Nb3Sn coils is 2000 A/cm2and 2400 A/cm2for the NbTi magnet. In this paper, we present design considerations and details, construction techniques, and operational results of these coils.
No takes yet. Share an insight, caveat, or question.
Zbasnik et al. (1987) studied this question.
Synapse has enriched 3 closely related papers on similar clinical questions. Consider them for comparative context: