Key result
An unusually located accessory atrioventricular connection was found bridging the atrioventricular ring epicardially from the base of the right atrial appendage directly to the right ventricle.
Case Report (n=1)
Answers are grounded in this paper and cite their sources.
The identification of an epicardial accessory pathway from the right atrial appendage to the right ventricle provides anatomical insight that may explain some failures of endocardial radiofrequency catheter ablation.
Atrial and ventricular attachments of accessory atrioventricular connections have classically been localized to adjacent atrial and ventricular tissues, and this principle is responsible for the widespread success of radiofrequency catheter ablation. We present anatomical evidence of an unusually located accessory atrioventricular connection, which bridged the atrioventricular ring epicardially, directly from the base of the right atrial appendage to the right ventricle. This observation might offer a new insight into unusual accessory atrioventricular connection locations and may explain why some endocardial radiofrequency catheter ablation procedures might fail.
No takes yet. Share an insight, caveat, or question.
Milstein et al. (1997) conducted a case report in Accessory atrioventricular connection (n=1). An unusually located accessory atrioventricular connection was found bridging the atrioventricular ring epicardially from the base of the right atrial appendage directly to the right ventricle.
Synapse has enriched 10 related papers. Consider them for comparative context: