Key result
Type 2 diabetes mellitus was an independent predictor of 5-year mortality following LVAD implantation compared to patients without diabetes (38.7% vs 24.4%; HR 2.09, 95% CI 1.34-2.84, P=0.004).
Why the study?
Type 2 DM is a frequent comorbidity in advanced heart failure requiring an LVAD implant, but its impact on early and long-term outcomes needed evaluation.
Does type 2 diabetes mellitus increase mortality in patients with advanced heart failure undergoing LVAD implantation?
Cohort (n=154)
No
Does type 2 diabetes mellitus increase mortality in patients with advanced heart failure undergoing LVAD implantation?
Hazard Ratio: 2.09 (95% CI 1.34–2.84)
Absolute Event Rate: 38.7% vs 24.4%
p-value: p=0.004
Type 2 diabetes is an independent predictor of long-term (5-year) mortality following continuous flow LVAD implantation, though short- and intermediate-term mortality rates are similar to non-diabetic patients.
DM associated with higher 5-year mortality after LVAD; leaves open whether glycemic optimization improves long-term survival.
OBJECTIVES: Type 2 diabetes mellitus (DM) is a frequent comorbidity among patients suffering from advanced heart failure necessitating a left ventricular assist device (LVAD) implant. The goal of this study was to evaluate the impact of type 2 DM on early and long-term outcomes of patients following an LVAD implant. METHODS: We performed an observational cohort study in a large tertiary care centre in Israel. All data of patients who underwent a continuous flow LVAD implant between 2006 and 2020 were extracted from our departmental database. Patients were divided into 2 groups: group I (patients without diabetes) and group II (patients with diabetes). We compared short-term (30-day and 3-month) mortality, intermediate-term (1- and 3-year) mortality and long-term (5 year) mortality between the 2 groups. RESULTS: The study population included 154 patients. Group I (patients without diabetes) comprised 88 patients and group II (patients with diabetes) comprised 66 patients. The mean follow-up duration was 38.2 ± 30.3 months. Short- and intermediate-term mortality (30 days, 1 year and 3 years) was higher in the group with DM compared with the group without DM but did not reach any statistically significant difference: 16.1% vs 9.8% (P = 0.312), 24.2% vs 17.3% (P = 0.399) and 30.6% vs 21.9% (P = 0.127) respectively. Long-term 5-year mortality was significantly higher in the group with DM compared to the group without: 38.7% vs 24.4% (P = 0.038). Furthermore, predictors of long-term mortality included diabetes (hazard ratio 2.09, confidence interval 1.34-2.84, P = 0.004), as demonstrated by regression analysis. CONCLUSIONS: Patients with diabetes and those without diabetes have similar 30-day and short- and intermediate-term mortality rates. The mortality risk of diabetic patients begins to increase 3 years after an LVAD implant. Diabetes is an independent predictor of long-term, 5-year mortality after an LVAD implant. CLINICAL TRIAL REGISTRATION: Ethical Committee of Sheba Medical Centre, Israel, on 2 December 2014, Protocol 4257.
No takes yet. Share an insight, caveat, or question.
Kogan et al. (2021) conducted a cohort in advanced heart failure necessitating a left ventricular assist device (LVAD) implant (n=154). Type 2 diabetes mellitus vs. Patients without diabetes was evaluated on Long-term (5-year) mortality (HR 2.09, 95% CI 1.34-2.84, p=0.004). Type 2 diabetes mellitus was an independent predictor of 5-year mortality following LVAD implantation compared to patients without diabetes (38.7% vs 24.4%; HR 2.09, 95% CI 1.34-2.84, P=0.004).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: