This is the authors' abstract. We don't add key points for this paper.
In response to reports of discrepant in vitro assays of high-purity concentrates, a double-blind crossover study of in vivo recovery and half-life of two brands of monoclonal-antibody-purified factor VIII concentrates (Monoclate and Hemofil-M) was performed in 23 patients with hemophilia A. In vivo recoveries were close to values predicted from the labelled unitage when plasma samples were assayed by a one-stage method. When a two-stage assay was used, lower recoveries were calculated and the recovery with Hemofil-M was slightly but significantly lower than that with Monoclate. The concentrates were re-assayed in vitro by the two-stage method. Monoclate (which is assayed by the manufacturer using a two-stage method) contained 97% of the labelled potency and Hemofil-M (which is assayed by the manufacturer using a one-stage method) contained 81% of the labelled potency. Differences in in vitro and in vivo assay methods contribute to disparities between expected and observed factor VIII recovery. Clearance of Hemofil-M was significantly faster than that of Monoclate, but volume of distribution at the steady state, mean residence time, and plasma half-disappearance times of the two concentrates were not significantly different.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Kasper et al. (1991) studied this question.