Answers are grounded in this paper and cite their sources.
Electrostatic scanning micromirrors made of single-crystal silicon from a SOI (silicon-on-insulator) wafer using self-aligned and localized plastic deformation of silicon have been demonstrated. Localized plastic deformation is achieved by selective Joule heating of silicon structures while the whole substrate is kept at low temperature. Novel designs for torsional springs to prevent the buckling problem due to the non-uniform thermal expansion by localized heating are presented and the optimal range of electric power for successful Joule heating is discussed. The prototype micromirror is actuated by self-aligned vertical comb sets at a measured resonant frequency of 4.13 kHz with optical scanning angles up to 50.9° under driving voltages of 30 V dc plus 14 V ac . After continuous operation of 20 billion cycles (56 days) at the maximum scanning angle, the device shows no observable signs of degradation or fatigue.
No takes yet. Share an insight, caveat, or question.
Kim et al. (2005) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: