Key result
Among 29 fatal cases of ruptured abdominal aortic aneurysm, contributing errors included failure to perform elective aneurysmectomy (12 patients), diagnostic delay (9), and technical error (8).
Why the study?
What are the determinants of failure and fatal errors in the treatment of ruptured abdominal aortic aneurysms?
Observational (n=29)
Yes
What are the determinants of failure and fatal errors in the treatment of ruptured abdominal aortic aneurysms?
Answers are grounded in this paper and cite their sources.
Identifying and avoiding specific errors in diagnosis, timing of surgery, and intraoperative technique may reduce mortality in patients with ruptured abdominal aortic aneurysms.
One must identify those fatal errors in the treatment of patients with ruptured abdominal aortic aneurysms (AAAs) to improve future treatment and reduce mortality. Our vascular registry identified 29 patients with ruptured AAAs who died following admission to the UCLA Hospital, Los Angeles, and the Sepulveda (Calif) Veterans Administration Hospital between 1971 and 1981. Review of the records identified four categories of error that contributed to death. These included failure to proceed with elective aneurysmectomy in 12 patients with known AAAs, error in the diagnosis of aortic rupture that led to delay in getting nine patients to the operating room, intraoperative technical error that produced venous injury in eight patients, and undue delay in anesthetic induction in four patients. Following the outline of a careful treatment approach should further reduce the mortality in the treatment of patients with ruptured AAAs.
No takes yet. Share an insight, caveat, or question.
Jo Carol Hiatt (1984) conducted an observational in Ruptured abdominal aortic aneurysm (n=29). Errors in treatment was evaluated on Categories of error contributing to death. Among 29 fatal cases of ruptured abdominal aortic aneurysm, contributing errors included failure to perform elective aneurysmectomy (12 patients), diagnostic delay (9), and technical error (8).
Synapse has enriched 10 related papers. Consider them for comparative context: