Answers are grounded in this paper and cite their sources.
Using a calcium-containing heparin preparation for anticoagulation, we determined [Ca2+], the mean concentration of ionized calcium, in whole blood of 120 healthy blood-donors to be 1.23 (SD 0.04) mmol/L. Similarly, for 50 intensive-care patients selected without conscious bias, the correlation between [Ca2+] in serum (mean 1.15, SD 0.10 mmol/L) and in whole-blood samples anticoagulated with the same heparin preparation (mean 1.15, SD 0.09 mmol/L) was very good (r = 0.95). Storing samples anaerobically on ice for as long as 2 h did not alter whole-blood [Ca2+]. On the other hand, various concentrations of calcium-free heparin preparations all induced a significant decrease in measured [Ca2+]. By using whole-blood samples, rather than plasma or serum, for [Ca2+] determination with a calcium-selective electrode, repetitive measurements can be made with simple handling procedures, facilitating rapid implementation of appropriate therapeutic measures for critically ill patients.
No takes yet. Share an insight, caveat, or question.
Urban et al. (1985) studied this question.