Key result
High-concentration sodium chloride solutions increased the derived rate of stable intracavitary ECG to 97.78% and 98.63% compared to 93.90% with 0.9% sodium chloride.
Why the study?
Clinical studies were lacking on the use of high-concentration sodium chloride solutions for intracavitary ECG-guided catheter tip localization during arm infusion port implantation.
Does the use of high-concentration sodium chloride solutions (5.45% or 10%) improve the stability of intracavitary ECG and reduce localization time compared to 0.9% sodium chloride solution in cancer patients undergoing arm infusion port implantation?
RCT (n=657)
Random number table
No
Does the use of high-concentration sodium chloride solutions (5.45% or 10%) improve the stability of intracavitary ECG and reduce localization time compared to 0.9% sodium chloride solution in cancer patients undergoing arm infusion port implantation?
Using 5.45% or 10% sodium chloride solutions as conductive media significantly improves the stability of intracavitary ECG signals and reduces localization time compared to 0.9% normal saline during arm infusion port implantation.
Answers are grounded in this paper and cite their sources.
Higher-concentration saline improves ECG signal quality in port placement; hypothesis-generating and should not yet change practice.
At present, there are few clinical studies on the application of high-concentration sodium chloride solutions in intracavitary ECG-guided catheter tip localization during the arm infusion port implantation. This study observed the effects of sodium chloride solutions with different concentrations on intracavitary ECG-guided arm infusion port implantation in the patients with cancer. The 657 patients receiving arm infusion port implantation in our hospital between January 2020 and August 2021 were randomly divided into 0.9% sodium chloride solution conduction group (group A), 5.45% sodium chloride solution conduction group (group B) and 10% sodium chloride solution conduction group (group C). The derived rate of stable intracavitary ECG, the occurrence rate of characteristic P wave, the time used for catheter tip localization and the optimal position rate of catheter tip were compared between the three groups. The derived rate of stable intracavitary ECG was significantly higher in the group B (97.78%) and group C (98.63%) than in the group A (93.90%) (all P < 0.05). The occurrence rate of characteristic P wave was also significantly higher in the group B (96.89%) and group C (97.72%) than in the group A (88.73%) (all P < 0.001). The time used for catheter tip localization was significantly shorter in the group B [(49.73 ± 8.15) s] and group C [(48.27 ± 8.61) s] than in the group A [(69.37 ± 19.99) s] (all P < 0.001). There was no significant difference in the optimal position rate of catheter tip among the three groups (P > 0.05). The 5.45% and 10% sodium chloride solutions are significantly superior comparing with 0.9% sodium chloride solution in the derived rate of stable intracavitary ECG, occurrence rate of characteristic P wave and time used for catheter tip localization, but there were no significant differences between 5.45 and 10% sodium chloride solutions. Moreover, the 5.45% sodium chloride solution is closer to physiological state comparing with 10% sodium chloride solution, so the 5.45% sodium chloride solution may be recommended for the intracavitary ECG-guided arm infusion port implantation.
No takes yet. Share an insight, caveat, or question.
Dong et al. (2022) conducted an RCT in Cancer requiring arm infusion port implantation (n=657). 5.45% and 10% sodium chloride solutions vs. 0.9% sodium chloride solution was evaluated on Derived rate of stable intracavitary ECG (p=< 0.05). High-concentration sodium chloride solutions increased the derived rate of stable intracavitary ECG to 97.78% and 98.63% compared to 93.90% with 0.9% sodium chloride.
Synapse has enriched 10 related papers. Consider them for comparative context: