Key result
The cold pressor test elicited a higher systolic blood pressure increase in pregnant women who later developed pre-eclampsia compared to those who remained healthy.
Why the study?
Does the blood pressure response to a cold pressor test predict the development of pre-eclampsia in pregnant women?
Cohort (n=123)
No
Does the blood pressure response to a cold pressor test predict the development of pre-eclampsia in pregnant women?
An increased blood pressure response to the cold pressor test between 16-20 weeks of gestation may serve as an early marker for the subsequent development of pre-eclampsia.
Answers are grounded in this paper and cite their sources.
May support cold pressor response as early pre-eclampsia marker; leaves open prospective validation before clinical adoption.
OBJECTIVES: Recent data indicate an increased vascular reactivity due to an overactivity of the sympathetic nervous system in women with pre-eclampsia. We therefore evaluated whether this increased vascular reactivity can be detected prior to the clinical manifestation of preeclampsia by the use of a physiological stimulus. DESIGN: Prospective data collection. SETTING: Clinic of Obstetrics and Gynecology in a 2000 bed tertiary care hospital. PARTICIPANTS: One hundred and twenty-three pregnant women between the 16th to 20th week of gestation. INTERVENTIONS: A cold pressor test was performed by positioning an ice-bag on the forehead of the woman for 3 min. Blood pressure and heart rate were monitored by a continuous, noninvasive blood pressure measurement device during the stimulus and after removal of the icebag. A clinical follow-up was carried out by review of the charts after delivery to identify those women who have developed pre-eclampsia. RESULTS: Ten (8%) out of 123 pregnant women developed pre-eclampsia. During the cold pressor test systolic as well as diastolic blood pressure increased significantly and was more pronounced in women developing pre-eclampsia compared with healthy pregnant women (systolic blood pressure: 14.2 +/- 5.5 versus 8.5 +/- 7.2 mmHg, P= 0.02; diastolic blood pressure: 7.3 +/- 4.9 versus 3.9 +/- 4.7 mmHg, P=0.03). The change in heart rate was similar between both groups (8 +/- 2.6 versus 10.4 +/- 6.4 beats/min, not significant). CONCLUSIONS: An increased vasoconstrictive response to a physiological stimulus is present in women with pre-eclampsia as a sign of an increased vascular reactivity prior to clinical manifestation of the disease. The cold pressor test may be a suitable diagnostic tool to identify women, who will develop pre-eclampsia. However, future studies in larger cohorts are required to establish the final value of this test.
No takes yet. Share an insight, caveat, or question.
Woisetschläger et al. (2000) conducted a cohort in Pre-eclampsia (n=123). Cold pressor test vs. Healthy pregnant women was evaluated on Increase in systolic blood pressure during the cold pressor test (mmHg) (p=0.02). The cold pressor test elicited a higher systolic blood pressure increase in pregnant women who later developed pre-eclampsia compared to those who remained healthy.
Synapse has enriched 10 related papers. Consider them for comparative context: