Key result
Overall cumulative survival at 3 years was 51% for the Edwards SAPIEN valve versus 60% for the Medtronic CoreValve, though survival was similar in transfemorally treated patients.
Why the study?
Does the Edwards SAPIEN valve compared to the Medtronic CoreValve affect 3-year survival in patients undergoing TAVI who are not candidates for surgery?
Cohort (n=861)
Yes
Does the Edwards SAPIEN valve compared to the Medtronic CoreValve affect 3-year survival in patients undergoing TAVI who are not candidates for surgery?
In a real-world registry of patients refused for surgery, midterm 3-year survival after transfemoral TAVI was similar between the Edwards SAPIEN and Medtronic CoreValve systems when stratified by baseline risk.
Answers are grounded in this paper and cite their sources.
Similar survival after transfemoral TAVI with either valve; leaves open differential effects by access route in high-risk patients.
OBJECTIVE: To assess midterm (3 years) clinical outcomes of transcatheter aortic valve implantation (TAVI) in Belgium using the Edwards SAPIEN valve or the Medtronic CoreValve transcatheter heart valve (THV). BACKGROUND: Medium and long term follow-up data of both THVs are still relatively scarce, although of great clinical relevance for a relatively new but rapidly expanding treatment modality. Therefore, reporting mid- and long term clinical outcome data, coming from large "real world" national registries, remains contributive. METHODS: Between December 2007 and March 2012, 861 "real world" patients who were not candidates for surgical aortic valve replacement as decided by the local heart teams, underwent TAVI at 23 sites. Eleven sites exclusively used SAPIEN THV (n = 460), while 12 exclusively used CoreValve THV (n = 401). Differences in clinical outcomes by valve system were assessed, according to access route and baseline EuroSCORE risk profile (<10%: low, 10-20%: intermediate and >20%: high risk). RESULTS: Overall cumulative survival at 3 years was 51% for SAPIEN vs. 60% for CoreValve (P = 0.021). In transfemorally treated patients, SAPIEN and CoreValve had similar survival at 3 years for each of the baseline EuroSCORE cohorts (low risk: 72% vs. 76%, P = 0.45; intermediate risk: 62% vs. 59%, P = 0.94; high risk: 48% vs. 53%, P = 0.65). CONCLUSION: Cumulative midterm 3 year survival after transfemoral TAVI in "real world" patients refused for surgery with similar baseline EuroSCORE risk profile is not different between SAPIEN or CoreValve.
No takes yet. Share an insight, caveat, or question.
Collas et al. (2015) conducted a cohort in Aortic valve disease requiring TAVI (n=861). Edwards SAPIEN transcatheter heart valve vs. Medtronic CoreValve transcatheter heart valve was evaluated on Overall cumulative survival at 3 years (p=0.021). Overall cumulative survival at 3 years was 51% for the Edwards SAPIEN valve versus 60% for the Medtronic CoreValve, though survival was similar in transfemorally treated patients.