Key result
Valve-in-valve TAVR using a SAPIEN 3 Ultra valve and SENTINEL embolic protection device successfully resolved severe aortic insufficiency and improved symptoms to NYHA class II at 30 days.
Case Report (n=1)
Valve-in-valve TAVR with cerebral embolic protection can be a safe and effective treatment for high-risk patients with degenerated surgical bioprostheses and highly mobile flail leaflets.
Case highlights feasibility of urgent intervention in extreme-risk degenerated bioprosthesis; leaves open optimal strategies for mobile leaflet masses.
An 80-year-old woman with a history of surgical aortic valve replacement with a 21 mm St. Jude Medical Biocor porcine aortic valve 14 years prior presented with New York Heart Association (NYHA) class III symptoms, severe aortic insufficiency from a degenerated prosthesis, and a large echocardiographic mobile mass representing a highly mobile prosthetic leaflet. The patient worsened to NYHA class IV symptoms despite medical management. The Society of Thoracic Surgery mortality risk score was extremely high. However, a valve-in-valve transcatheter aortic valve replacement (TAVR) was found to be a reasonable option. We used a 20 mm SAPIEN 3 Ultra valve (Edwards Lifesciences Inc., Irvine, CA, USA) with a SENTINEL embolic protection device (Boston Scientific, Marlborough, MA, USA). During valve deployment, the echocardiographic mobile mass was visually pinned between the new TAVR valve and the surgical bioprosthetic valve. No large embolic debris was noted within the embolic protection device, and the patient remained without any new focal neurologic deficits in the perioperative period and at the 30-day follow-up. The severe aortic insufficiency resolved, and the patient clinically improved to NYHA class II symptoms.
No takes yet. Share an insight, caveat, or question.
Abela et al. (2021) conducted a case report in Severe aortic insufficiency from a degenerated bioprosthesis with a flail prosthetic leaflet (n=1). Valve-in-valve transcatheter aortic valve replacement (TAVR) with a SAPIEN 3 Ultra valve and SENTINEL embolic protection device was evaluated on Resolution of aortic insufficiency and clinical improvement. Valve-in-valve TAVR using a SAPIEN 3 Ultra valve and SENTINEL embolic protection device successfully resolved severe aortic insufficiency and improved symptoms to NYHA class II at 30 days.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: