This study examined postimplantation morphological changes in 23 Carpentier-Edwards Perimount bioprostheses explanted at a single center between 1981 and 2005.
Observational (n=23)
No
The study aims to describe the postimplantation morphological changes in explanted Carpentier-Edwards Perimount bioprosthetic heart valves.
Answers are grounded in this paper and cite their sources.
May inform durability counseling for Perimount valves; leaves open mechanisms of degeneration for prospective study.
Valvular heart disease is a growing medical problem in the 20th century, with an increasing number of patients undergoing valve repair and replacement surgery. 1 Worldwide, more than 55% of implanted prosthetic heart valves (PHV) are mechanical heart valves (MHV) and 45% are bioprosthetic heart valves (BHV). 2 BHV more closely resemble native valves in design than do mechanical valves, and are, therefore, better able to mimic normal blood flow patterns through a three-cusp valve. 1 BHV may comprise porcine aortic tissue or bovine pericardium.The Carpentier-Edwards Perimount (CEP) bioprosthesis is a second-generation pericardial valve made of bovine (calf) pericardial tissue. 1 The tissue is cut from selected regions of bovine pericardium and mounted on a lightweight Elgiloy frame covered with a porous, knitted polytetrafluoroethylene (PTFE) fabric.The sewing ring is made of molded silicone rubber covered with PTFE cloth, which enables the surgeon to sew the valve into place.Few studies have examined the postimplantation morphological changes in a series of explanted CEP.Herein, we describe such changes in 23 CEP valves, explanted at our institution since the start of their use in 1981. MATERIALS AND METHODSFrom 1981 to 2005, a total of 1042 Carpentier-Edwards bovine pericardial bioprostheses (CEP) were implanted in our hospital by one group of surgeons.CEP bioprostheses explanted at surgery or autopsy were examined at the Toronto General Hospital Department of pathology by one pathologist (JB) with an interest in cardiovascular pathology and prosthetic heart valves.
No takes yet. Share an insight, caveat, or question.
Butany et al. (2007) conducted an observational in Valvular heart disease (n=23). Carpentier-Edwards Perimount (CEP) bioprosthesis was evaluated on Postimplantation morphological changes. This study examined postimplantation morphological changes in 23 Carpentier-Edwards Perimount bioprostheses explanted at a single center between 1981 and 2005.
Synapse has enriched 10 related papers. Consider them for comparative context: