Key result
A sequential anticoagulation strategy switching between warfarin and unfractionated heparin during pregnancy in two women with mechanical heart valves resulted in successful deliveries with minimal postpartum hemorrhage.
Why the study?
Patients with prosthetic mechanical heart valves require lifelong anticoagulation, especially during pregnancy which increases thrombosis risk.
Does a sequential regimen of warfarin and unfractionated heparin ensure safe delivery and minimize hemorrhage in pregnant patients with mechanical heart valves?
Case Report (n=2)
Does a sequential regimen of warfarin and unfractionated heparin ensure safe delivery and minimize hemorrhage in pregnant patients with mechanical heart valves?
A sequential anticoagulation strategy alternating between warfarin and unfractionated heparin based on gestational age can lead to successful deliveries with minimal bleeding complications in pregnant women with mechanical heart valves.
Answers are grounded in this paper and cite their sources.
Case reports support individualized peripartum anticoagulation in mechanical valve pregnancies; leaves open optimal protocols pending prospective data.
Patients with prosthetic mechanical heart valves require a life-long anticoagulation. This is more so during pregnancy which increases the risk of thrombosis. We present two pregnant patients with prosthetic mechanical valves managed up to delivery. All the patients were on warfarin before conception which was changed to unfractionated heparin after confirmation of pregnancy. At 14 weeks gestation, they were changed back to warfarin until 36 weeks gestation. Unfractionated heparin was reintroduced until delivery. All the patients had minimal postpartum hemorrhage. Mrs. XX, one of them, had four successful deliveries since the placement of mechanical valve. Pregnancy for a woman mechanical valve poses a greater risk to both the mother and the fetus. This group of women should have preconception care in a specialized program.
No takes yet. Share an insight, caveat, or question.
Usman et al. (2020) conducted a case report in Pregnant patients with prosthetic mechanical heart valves (n=2). Sequential anticoagulation (warfarin and unfractionated heparin) was evaluated on Postpartum hemorrhage and successful delivery. A sequential anticoagulation strategy switching between warfarin and unfractionated heparin during pregnancy in two women with mechanical heart valves resulted in successful deliveries with minimal postpartum hemorrhage.
Synapse has enriched 10 related papers. Consider them for comparative context: