Key result
The Aeson bioprosthetic total artificial heart successfully bridged a 58-year-old man with a severe post-infarction ventricular septal defect to heart transplantation after 26 days of support.
Why the study?
Post-infarction ventricular septal defects have high mortality rates, and surgical or interventional treatments are sometimes technically unfeasible and do not always ensure good outcomes.
Does the Aeson bioprosthetic total artificial heart allow safe bridging to transplantation in a patient with post-infarction ventricular septal rupture and cardiogenic shock?
Case Report (n=1)
No
Does the Aeson bioprosthetic total artificial heart allow safe bridging to transplantation in a patient with post-infarction ventricular septal rupture and cardiogenic shock?
Answers are grounded in this paper and cite their sources.
The Aeson bioprosthetic total artificial heart can serve as a successful bridge to transplantation in patients with complex post-infarction ventricular septal defects unsuitable for conventional surgery or interventional therapy.
Background: Post-infarction ventricular septal defects remain one of the most feared complications after myocardial infarction with high mortality rates. In special cases, surgical or interventional treatment strategies are technically not feasible and do not always lead to a good outcome. Case presentation: A 58-year-old male patient in cardiogenic shock with a very large ventricular septal (VSD) defect (4.9 cm × 5 cm) due to myocardial infarction was presented in our department. Acute stabilization was achieved using peripheral venoarterial extracorporeal membrane oxygenation (VA-ECMO) support. Neither surgical nor interventional therapy was considered as a sufficient option due to the unsuitable anatomy of the VSD and the patient was listed for heart transplantation. After 2 weeks on ECMO, bleeding and infectious complications occurred. Due to organ shortage, urgent implantation of the bioprosthetic total artificial heart (TAH) Aeson device (CARMAT) remained the only useful strategy to achieve a mid- or long-term bridge to transplantation. After successful implantation and good recovery with the Aeson device, the patient was transplanted 4 weeks after implantation. Conclusion: Post-infarction ventricular septal defects are highly challenging and are commonly associated with a poor prognosis. The implantation of the new Aeson TAH device is a promising therapeutic option, allowing a safe and long-term bridging to heart transplantation.
No takes yet. Share an insight, caveat, or question.
Huenges et al. (2023) conducted a case report in Post-infarction ventricular septal rupture (n=1). Aeson bioprosthetic total artificial heart (CARMAT) was evaluated on Successful bridge to heart transplantation. The Aeson bioprosthetic total artificial heart successfully bridged a 58-year-old man with a severe post-infarction ventricular septal defect to heart transplantation after 26 days of support.