Key result
Aortic valve replacement in patients with aortic stenosis significantly reduced common carotid artery intima-media thickness from 0.741 mm to 0.627 mm at 6 months (P<0.0001).
Why the study?
Does aortic valve replacement improve arterial remodeling of the common carotid artery in patients with aortic stenosis?
Observational (n=11)
Does aortic valve replacement improve arterial remodeling of the common carotid artery in patients with aortic stenosis?
Absolute Event Rate: 0.627% vs 0.741%
p-value: p=<0.0001
Aortic valve replacement in patients with aortic stenosis leads to a reduction in common carotid artery intima-media thickness, likely mediated by increased wall shear stress.
AVR was associated with carotid IMT reduction in AS; leaves open clinical relevance and need for RCTs.
BACKGROUND AND PURPOSE: Aortic stenosis, causing flow abnormalities, disturbs the normal hemodynamics in the common carotid arteries. The aim of the present study was to investigate the remodeling process of the common carotid arteries after surgical correction of aortic stenosis. METHODS: Eleven subjects with aortic stenosis were studied before and 1 and 6 months after aortic valve replacement. Arterial diameter, intima-media thickness (IMT), and flow velocity were measured by echo-Doppler examination. Shear stress, blood flow, and pulsatility index were calculated. Blood viscosity and hematocrit were measured by standard methods. A control group was also enrolled. RESULTS: Before surgery, compared with controls, patients had lower systolic peak velocity but higher mean and end-diastolic velocity. Arterial diameter, IMT, and blood flow were comparable in the 2 groups. Blood viscosity, hematocrit, wall shear stress, and pulsatility index were markedly lower in patients. After surgery, IMT was reduced (0.741+/-0.152 versus 0.627+/-0.108 mm before and 6 months after surgery, respectively; P<0.0001), and hematocrit and blood viscosity increased, leading to increased wall shear stress (mean wall shear stress, 7.83+/-1.97 versus 9.65+/-3.12 dyne/cm(2) before and 6 months after surgery, respectively; P<0.02). CONCLUSIONS: The present results demonstrate that aortic valve replacement, in subjects with aortic stenosis, leads to reduction of the common carotid artery IMT. Wall shear stress is increased after the intervention and probably mediates the remodeling process.
No takes yet. Share an insight, caveat, or question.
Irace et al. (2002) conducted an observational in Aortic stenosis (n=11). Aortic valve replacement vs. Baseline (before surgery) and control group was evaluated on Common carotid artery intima-media thickness (IMT) (p=<0.0001). Aortic valve replacement in patients with aortic stenosis significantly reduced common carotid artery intima-media thickness from 0.741 mm to 0.627 mm at 6 months (P<0.0001).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: