January 1, 1997British Journal of Radiology

A simple and reproducible method for assessing intimal-medial thickness of the common carotid artery.

View Full Paper
Ask AI
Bookmark
Share

Key result

Measurement of common carotid artery intimal-medial thickness was highly reproducible, with an interobserver mean absolute difference of 0.0480 mm and a coefficient of variation of 8.98%.

Population

30 healthy volunteers (three groups of 10)

Design

Other

Follow-up

2 weeks

Authors

PSPaul S. SidhuKing's College LondonSDSujal R. DesaiGuy's and St Thomas' NHS Foundation Trust

Discussion

Loading...

Member takes

Implication

Supports reliable CCA IMT use in vascular protocols; leaves open its added value for risk stratification or outcomes.

Study Design

Type

Observational (n=30)

Structured PICO

P
Population
30 healthy volunteers evaluated to assess the reproducibility of common carotid artery intimal-medial thickness measurements over a 2-week period.
E
Exposure
Ultrasound assessment of intimal-medial thickness (IMT) of the common carotid artery
O
Outcome
Intra- and inter-observer reproducibility of IMT measurementssurrogate

The described ultrasound method for estimating common carotid artery IMT provides reproducible and reliable measurements suitable for routine practice.

Cite This Study

Sidhu et al. (1997) conducted an observational in Healthy volunteers (n=30). Measurement of intimal-medial thickness of the common carotid artery was evaluated on Reproducibility of IMT measurement (mean absolute difference, coefficient of variation, and coefficient of repeatability). Measurement of common carotid artery intimal-medial thickness was highly reproducible, with an interobserver mean absolute difference of 0.0480 mm and a coefficient of variation of 8.98%.

synapsesocial.com/papers/6a93ca3f17272e2ca0f2c2e5https://doi.org/10.1259/bjr.70.829.9059301
View Full Paper
Ask AI
Bookmark
Share

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Evaluation of a scoring system for extracranial carotid atherosclerosis extent with B-mode ultrasound.1986 · 160 citations
  2. 2High-resolution dynamic ultrasound imaging of the carotid bifurcation: a prospective evaluation.1982 · 67 citations
  3. 3Common carotid intima-media thickness measurement. A method to improve accuracy and precision.1994 · 59 citations
  4. 4Reproducibility of noninvasive ultrasonic measurement of carotid atherosclerosis. The Asymptomatic Carotid Artery Plaque Study.1992 · 215 citations
  5. 5High‐Resolution B‐Mode Ultrasound Reading Methods in the Atherosclerosis Risk in Communities (ARIC) Cohort1991 · 203 citations