Key result
A machine learning model using biosignal-based digital biomarkers obtained during spontaneous breathing trials predicted mechanical ventilation weaning success with an AUC of 0.81 (95% CI 0.70-0.92).
Why the study?
The study evaluated new features from biosignals containing diverse physiological response information to predict mechanical ventilation weaning outcomes.
Does a machine learning model using continuous biosignal data improve prediction of successful weaning from mechanical ventilation in ICU patients?
Observational (n=89)
Does a machine learning model using continuous biosignal data improve prediction of successful weaning from mechanical ventilation in ICU patients?
Effect estimate: AUC 0.81 (95% CI 0.70-0.92)
A machine learning model incorporating continuous biosignal data during spontaneous breathing trials shows promise in predicting successful extubation in ICU patients.
May aid weaning prediction via biosignals in ICU; hypothesis-generating and requires prospective validation before clinical adoption.
We evaluated new features from biosignals comprising diverse physiological response information to predict the outcome of weaning from mechanical ventilation (MV). We enrolled 89 patients who were candidates for weaning from MV in the intensive care unit and collected continuous biosignal data: electrocardiogram (ECG), respiratory impedance, photoplethysmogram (PPG), arterial blood pressure, and ventilator parameters during a spontaneous breathing trial (SBT). We compared the collected biosignal data’s variability between patients who successfully discontinued MV (n = 67) and patients who did not (n = 22). To evaluate the usefulness of the identified factors for predicting weaning success, we developed a machine learning model and evaluated its performance by bootstrapping. The following markers were different between the weaning success and failure groups: the ratio of standard deviations between the short-term and long-term heart rate variability in a Poincaré plot, sample entropy of ECG and PPG, α values of ECG, and respiratory impedance in the detrended fluctuation analysis. The area under the receiver operating characteristic curve of the model was 0.81 (95% confidence interval: 0.70–0.92). This combination of the biosignal data-based markers obtained during SBTs provides a promising tool to assist clinicians in determining the optimal extubation time.
No takes yet. Share an insight, caveat, or question.
Park et al. (2021) conducted an observational in Mechanical ventilation weaning (n=89). Biosignal-based digital biomarkers was evaluated on Prediction of weaning success (AUC 0.81, 95% CI 0.70-0.92). A machine learning model using biosignal-based digital biomarkers obtained during spontaneous breathing trials predicted mechanical ventilation weaning success with an AUC of 0.81 (95% CI 0.70-0.92).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: