Key result
Nitroglycerin infusion at 3.0 µg/kg/min significantly decreased systolic blood pressure from 102 mmHg to 80 mmHg (p<0.01) and systemic vascular resistance, indicating a decrease in afterload.
Why the study?
Does nitroglycerin decrease afterload in a canine model with constant venous return?
Does nitroglycerin decrease afterload in a canine model with constant venous return?
Absolute Event Rate: 80% vs 102%
p-value: p=<0.01
Nitroglycerin significantly decreases afterload (systolic blood pressure and systemic vascular resistance) in a canine model when venous return is held constant.
Hypothesis-generating in preload-controlled canine models; leaves open translation to human vasodilator therapy.
Nitroglycerin is considered to decrease both preload and afterload. To elucidate the actions of nitroglycerin on afterload, venous return was kept constant in this experiment. Three different doses of nitroglycerin, 0.3 microgram/kg/min, 1.0 microgram/kg/min, 3.0 micrograms/kg/min were administered into the ascending aorta of 6 mongrel dogs weighing over 20 kg. These doses of nitroglycerin were randomized in each of six procedures. The plasma concentration of nitroglycerin increased during 10 min of infusion, then it decreased exponentially. Heart rate, cardiac output and left atrial pressure did not change significantly at any dose of nitroglycerin. Systolic blood pressure and systemic vascular resistance (as indices of afterload) decreased significantly during nitroglycerin infusion, especially with the 3 micrograms/kg/min dose. These data suggest that nitroglycerin decreases the afterload. The effects appeared rapidly with administration and disappeared rapidly after cessation of the infusion.
No takes yet. Share an insight, caveat, or question.
Fujiwara et al. (1988) studied Hemodynamics (Animal Model) (n=6). Nitroglycerin vs. Control state (before infusion) was evaluated on Systolic blood pressure at 3.0 µg/kg/min (p=<0.01). Nitroglycerin infusion at 3.0 µg/kg/min significantly decreased systolic blood pressure from 102 mmHg to 80 mmHg (p<0.01) and systemic vascular resistance, indicating a decrease in afterload.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: