Answers are grounded in this paper and cite their sources.
A magnetic garnet thin film was used as a polarization rotator to reverse the weak contrast of magnetic domain images in a polarizing microscope. It was installed in a microscope and magnetized alternately at the video frame rate along the optical axis. This enabled the contrast of magnetic images to be improved by subtracting reversed images without disturbing the domain configuration to acquire a nonmagnetic background image. The contribution of magnetic circular dichroism of the garnet rotator was also studied. When the rotation θg and the ellipticity χg of the rotator match those of domains of Kerr rotation, θk, and ellipticity, χk, to be observed, (i.e., θkθgχkχg≳0,) the domain image contrast is enhanced compared to the absence of an ellipticity in the rotator. On the other hand, when θkθgχkχg<0 the contrast is deteriorated, but with the help of a quarter-wave plate the contrast is enhanced. The differential acquisition of domain patterns was also performed at an interval of 100 ms for moving domains which cannot be observed without differential technique.
No takes yet. Share an insight, caveat, or question.
Numata et al. (1991) studied this question.