Key result
Thoracoscopy-assisted mitral valve replacement with domestically manufactured pipeline products reduced postoperative hospitalization time compared to conventional open-heart surgery and lowered costs compared to imported products.
Why the study?
Does thoracoscopy-assisted mitral valve replacement with tricuspid valvuloplasty using domestically manufactured cardiopulmonary bypass products provide safe and cost-effective outcomes compared to conventional surgery or imported products in patients with valvular heart disease?
Observational (n=135)
No
Does thoracoscopy-assisted mitral valve replacement with tricuspid valvuloplasty using domestically manufactured cardiopulmonary bypass products provide safe and cost-effective outcomes compared to conventional surgery or imported products in patients with valvular heart disease?
Thoracoscopy-assisted mitral valve replacement with tricuspid valvuloplasty using domestically manufactured cardiopulmonary bypass products is safe, reduces hospital stay compared to conventional surgery, and lowers costs compared to imported products.
Answers are grounded in this paper and cite their sources.
May support shorter stays and lower costs with domestic products in thoracoscopic mitral surgery; leaves open need for randomized confirmation.
OBJECTIVE: To discuss the feasibility and experience of treating valvular heart diseases with thoracoscopy-assisted mitral valve replacement concomitant with tricuspid valvuloplasty, with domestically manufactured pipeline products for cardiopulmonary bypass. METHODS: A total of 135 patients with valvular heart disease were admitted to our hospital between January 2011 and January 2013. They received thoracoscopy-assisted mitral valve replacement concomitant with tricuspid valvuloplasty, with domestically manufactured pipeline products. A cardiopulmonary bypass with domestically-manufactured pipeline products was established during the surgery. The procedure was accomplished with the assistance of thoracoscopy through a small incision in the right chest wall. RESULTS: All 135 patients underwent a successful surgery, and were followed up for the duration of half a year to two years. None of them displayed any evidence of complications. Our procedure had the advantage of fewer complications and a significantly shortened time period for the patient care and hospitalization. As opposed to imported pipeline products for cardiopulmonary bypass, our procedure had the advantage of similar clinical results at a lower cost. CONCLUSIONS: Thoracoscopy-assisted mitral valve replacement concomitant with tricuspid valvuloplasty was proved to be a safe and effective method for cardiopulmonary bypass, with the use of domestically manufactured pipeline products.
No takes yet. Share an insight, caveat, or question.
Cao et al. (2014) conducted an observational in Valvular heart disease (n=135). Thoracoscopy-assisted mitral valve replacement with domestically manufactured pipeline products vs. Conventional open-heart surgery was evaluated on Postoperative hospitalization time (days) (p=<0.05). Thoracoscopy-assisted mitral valve replacement with domestically manufactured pipeline products reduced postoperative hospitalization time compared to conventional open-heart surgery and lowered costs compared to imported products.
Synapse has enriched 10 related papers. Consider them for comparative context: