Key result
Intra-aortic filtration successfully captured a suture pledget during re-operation for aortic regurgitation and mitral valve replacement, preventing potential particle embolization.
Why the study?
Does intra-aortic filtration capture hazardous embolic materials during cardiac valve surgery?
Case Report (n=1)
Does intra-aortic filtration capture hazardous embolic materials during cardiac valve surgery?
Answers are grounded in this paper and cite their sources.
Intra-aortic filtration during cardiac surgery can successfully capture potentially hazardous embolic materials, such as suture pledgets, potentially preventing neurological complications.
Neurological complications after cardiac operations are mostly due to particle embolization. This case illustrates the embolic potential of any material. A 77-year-old lady underwent re-operation for homograft aortic regurgitation and mitral valve replacement. Intra-aortic filtration was used. After cardiopulmonary bypass the filter was found to have captured a pledget from a suture used to secure the mitral replacement device.
No takes yet. Share an insight, caveat, or question.
Mestres et al. (2007) conducted a case report in Homograft aortic regurgitation and mitral valve replacement (n=1). Intra-aortic filtration was evaluated on Capture of embolic material. Intra-aortic filtration successfully captured a suture pledget during re-operation for aortic regurgitation and mitral valve replacement, preventing potential particle embolization.