This paper describes the analysis, design, and testing of a six-port automatic network analyzer. A new calibration procedure is derived from a matrix description of the six-port network. The calibration constants appear as the soIution of an eigenvalue problem resulting in new insights and faster numerical computation. A programmable calculator-controlled six-port system was designed to measure S/sub 11/ and S/sub 21/ over the frequency range 2-18 GHz without perturbing the device under test. Measurements on the completed system taken from 7-12 GHz show that results within 1 percent can be obtained.
No takes yet. Share an insight, caveat, or question.
Cronson et al. (1977) studied this question.