A series of centrifuge model tests of an offshore wind turbine (OWT) monopile foundation were conducted using the 500 gtonne capacity beam centrifuge of the ETH Zurich Geotechnical Centrifuge Centre. The paper establishes a meticulous experimental procedure for realistic simulation of OWT monopile foundations subjected to storm loading, revealing soil drainage effects on cyclic monopile response. The model steel monopile, with a ratio of embedded length over diameter, L/D = 3.75, was installed in fully saturated dense Ottawa F-65 sand of target relative density Dr = 75%. The key aspects of the centrifuge modelling campaign, including: (i) construction of the monopile model including internal strain gauges; (ii) air-pluviation of the sand through a custom-built ‘curtain’ raining system; (iii) extensive instrumentation with pore pressure transducers and LVDTs; (v) sand saturation with 60 cp viscous fluid; and (vi) 1 g jacking of the monopile. After spinning up the model to 60 g, the monopile was subjected to lateral one-way sinusoidal and random storm loading using a specially designed hydraulic dynamic actuator that can apply load-controlled time histories in a frequency range of 4–100 Hz in model scale. Selected test results are presented, demonstrating that the experiments successfully captured the partial drainage effects on soil-monopile system response.