Key result
A fully automatic framework for left ventricular segmentation using shape-based B-spline explicit active surfaces achieved mean average distances of 1.81±0.59 mm at end-diastole and 1.98±0.66 mm at end-systole.
Why the study?
Does a shape-based B-spline explicit active surfaces framework improve left ventricular segmentation accuracy and efficiency in 3-D echocardiography compared to other state-of-the-art methods?
Does a shape-based B-spline explicit active surfaces framework improve left ventricular segmentation accuracy and efficiency in 3-D echocardiography compared to other state-of-the-art methods?
Answers are grounded in this paper and cite their sources.
A novel shape-based B-spline explicit active surfaces framework provides fast, fully automatic, and accurate left ventricular segmentation in 3-D echocardiography.
Cardiac volume/function assessment remains a critical step in daily cardiology, and 3-D ultrasound plays an increasingly important role. Fully automatic left ventricular segmentation is, however, a challenging task due to the artifacts and low contrast-to-noise ratio of ultrasound imaging. In this paper, a fast and fully automatic framework for the full-cycle endocardial left ventricle segmentation is proposed. This approach couples the advantages of the B-spline explicit active surfaces framework, a purely image information approach, to those of statistical shape models to give prior information about the expected shape for an accurate segmentation. The segmentation is propagated throughout the heart cycle using a localized anatomical affine optical flow. It is shown that this approach not only outperforms other state-of-the-art methods in terms of distance metrics with a mean average distances of 1.81±0.59 and 1.98±0.66 mm at end-diastole and end-systole, respectively, but is computationally efficient (in average 11 s per 4-D image) and fully automatic.
No takes yet. Share an insight, caveat, or question.
Queirós et al. (2017) studied Left ventricular segmentation in echocardiography. Shape-based B-spline explicit active surfaces framework vs. Other state-of-the-art methods was evaluated on Mean average distance at end-diastole and end-systole. A fully automatic framework for left ventricular segmentation using shape-based B-spline explicit active surfaces achieved mean average distances of 1.81±0.59 mm at end-diastole and 1.98±0.66 mm at end-systole.
Synapse has enriched 10 related papers. Consider them for comparative context: