Key result
The modified B-spline explicit active surfaces framework with uncoupled scaling enabled accurate semiautomatic left atrial segmentation in 3-D ultrasound compared to manual delineations.
Why the study?
Does the modified BEAS framework with scale uncoupling provide accurate semiautomatic left-atrial segmentation from 3-D ultrasound compared to manual delineation in healthy subjects?
Does the modified BEAS framework with scale uncoupling provide accurate semiautomatic left-atrial segmentation from 3-D ultrasound compared to manual delineation in healthy subjects?
Answers are grounded in this paper and cite their sources.
The modified BEAS framework with scale uncoupling enables accurate semiautomatic segmentation of the left atrium from 3-D ultrasound, facilitating reliable quantification of LA morphology and function.
Segmentation of the left atrium (LA) of the heart allows quantification of LA volume dynamics which can give insight into cardiac function. However, very little attention has been given to LA segmentation from three-dimensional (3-D) ultrasound (US), most efforts being focused on the segmentation of the left ventricle (LV). The B-spline explicit active surfaces (BEAS) framework has been shown to be a very robust and efficient methodology to perform LV segmentation. In this study, we propose an extension of the BEAS framework, introducing B-splines with uncoupled scaling. This formulation improves the shape support for less regular and more variable structures, by giving independent control over smoothness and number of control points. Semiautomatic segmentation of the LA endocardium using this framework was tested in a setup requiring little user input, on 20 volumetric sequences of echocardiographic data from healthy subjects. The segmentation results were evaluated against manual reference delineations of the LA. Relevant LA morphological and functional parameters were derived from the segmented surfaces, in order to assess the performance of the proposed method on its clinical usage. The results showed that the modified BEAS framework is capable of accurate semiautomatic LA segmentation in 3-D transthoracic US, providing reliable quantification of the LA morphology and function.
No takes yet. Share an insight, caveat, or question.
Almeida et al. (2015) studied Healthy subjects (n=20). B-spline explicit active surfaces (BEAS) framework with uncoupled scaling vs. Manual reference delineations was evaluated on Accuracy of semiautomatic LA segmentation and quantification of LA morphology and function. The modified B-spline explicit active surfaces framework with uncoupled scaling enabled accurate semiautomatic left atrial segmentation in 3-D ultrasound compared to manual delineations.
Synapse has enriched 10 related papers. Consider them for comparative context: