Key result
Early CIED pocket infections (<12 months) presented more with erythema and swelling (P<0.001), while late infections (≥12 months) had more pocket erosion (P=0.005) and valvular vegetations.
Why the study?
Do clinical features of CIED pocket infections differ between early (<12 months) and late (≥12 months) presentations?
Cohort (n=238)
Yes
Do clinical features of CIED pocket infections differ between early (<12 months) and late (≥12 months) presentations?
Clinical presentation of CIED pocket infections differs significantly based on time since the last procedure, with early infections showing localized inflammation and late infections showing erosion or endocarditis.
Answers are grounded in this paper and cite their sources.
Timing of CIED infection may aid clinical recognition of specific features; observational data leave open impact on diagnostic thresholds or outcomes.
BACKGROUND: Cardiovascular implantable electronic device (CIED) pocket infections are often related to recent CIED placement or manipulation, but these infections are not well characterized. The clinical presentation of CIED pocket infection, based on temporal onset related to last CIED procedure, deserves further study. METHODS: The MEDIC (Multicenter Electrophysiologic Device Infection Cohort) prospectively enrolled subjects with CIED infection. Subjects were stratified into those whose infection occurred <12 months (early) or ≥ 12 months (late) since their last CIED-related procedure. RESULTS: There were 132 subjects in the early group and 106 in the late group. There were more females (P = 0.009) and anticoagulation use (P = 0.039) in the early group. Subjects with early infections were more likely to have had a generator change or lead addition as their last procedure (P = 0.03) and had more prior CIED procedures (P = 0.023). Early infections were more likely to present with pocket erythema (P < 0.001), swelling (P < 0.001), and pain (P = 0.007). Late infections were more likely to have pocket erosion (P = 0.005) and valvular vegetations (P = 0.009). In bacteremic subjects, early infections were more likely healthcare-associated (P < 0.001). In-hospital and 6-month mortality were equivalent. CONCLUSION: A total of 45% of patients with CIED pocket infection presented >12 months following their last CIED-related procedure. Patients with early infection were more likely to be female, on anticoagulation, and present with localized inflammation, whereas those with late infection were more likely to have CIED erosion or valvular endocarditis.
No takes yet. Share an insight, caveat, or question.
Welch et al. (2014) conducted a cohort in Cardiovascular implantable electronic device (CIED) pocket infections (n=238). Early CIED pocket infection (<12 months since last procedure) vs. Late CIED pocket infection (≥12 months since last procedure) was evaluated on Clinical presentation of CIED pocket infection. Early CIED pocket infections (<12 months) presented more with erythema and swelling (P<0.001), while late infections (≥12 months) had more pocket erosion (P=0.005) and valvular vegetations.