Key result
CIED infections following initial implantation presented earlier and with more severe systemic manifestations, whereas infections after reoperation occurred later and were predominantly localized pocket infections.
Why the study?
Do clinical manifestations and outcomes of CIED infection differ between patients who underwent initial implantation versus reoperation?
Cohort (n=432)
Yes
Do clinical manifestations and outcomes of CIED infection differ between patients who underwent initial implantation versus reoperation?
Absolute Event Rate: 48.9% vs 70.1%
p-value: p=<0.001
CIED infections following initial implantation present earlier and more acutely with sepsis, whereas infections after reoperation present later and more indolently as localized pocket infections.
May guide differentiated monitoring after CIED procedures; leaves open whether implant history should inform prevention trials.
Objective: To explore differences in clinical manifestations and outcomes in those patients who develop infection after undergoing initial implantation versus reoperation. Methods: We compared cases of cardiac implantable electronic device (CIED) infection based on initial implantation versus reoperation from 11 centres. Results: There were 432 patients with CIED infection, 178 occurring after initial device placement and 254 after repeat reoperation. No differences were seen in age, sex or device type. Those with infection after initial implant had a higher Charlson Comorbidity Score (median 3 (IQR 2-6) vs 2 (IQR 1-4), p<0.001), shorter time since last procedure (median 8.9 months (IQR 0.9-33.3) vs 19.5 months (IQR 1.1-62.9), p<0.0001) and fewer leads (2.0±0.6vs 2.5±0.9, p<0.001). Pocket infections were more likely to occur after a reoperation (70.1%vs48.9%, p<0.001) and coagulase negative staphylococci (CoNS) was the most frequently isolated organism in this group (p=0.029). In contrast, initial implant infections were more likely to present with higher white cell count (10.5±5.1 g/dL vs 9.5±5.4 g/dL, p=0.025), metastatic foci of infection (16.9%vs8.7%, p=0.016) and sepsis (30.9%vs19.3%, p=0.006). There were no differences in in-hospital (7.9%vs5.2%, p=0.31) or 6-month mortality (21.9%vs14.0%, p=0.056). Conclusions: . In contrast, CIED infections after reoperation occur later, are due to CoNS, and have more indolent manifestations with primary localisation to the pocket.
No takes yet. Share an insight, caveat, or question.
Harper et al. (2018) conducted a cohort in Cardiac implantable electronic device (CIED) infection (n=432). Initial CIED implantation vs. Reoperation for generator change or lead addition was evaluated on Localised pocket infection (p=<0.001). CIED infections following initial implantation presented earlier and with more severe systemic manifestations, whereas infections after reoperation occurred later and were predominantly localized pocket infections.