Answers are grounded in this paper and cite their sources.
Transient processes are examined for a lossless, multiple-section transmission line terminated with resistive load. The signal components of the transmitted wave at the load end are examined in detail. The ringing effect is primarily due to two factors: (1) the voltage difference between the first arriving wave and the quasi-steady voltage and (2) the voltage signals generated by internal reflection-transmission processes which successively arrive at the output after the first arriving wave. By properly choosing the values of the characteristic impedances of the signal line it is found that a multiple-section line in which the sections are of equal length can provide high-quality signals to the load. Several examples are given to illustrate this methodology.>
No takes yet. Share an insight, caveat, or question.
C.‐W. Hsue (1989) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: