To identify and account for the effects from cryocontamination, the infrared spectral transmittances of cryofilms formed by CO2, H2O, and NH3 were measured. These 0.25–14-μm-thick films were cryopumped onto 20-, 80-, and in one case 50-K germanium substrates; the deposition pressures for the films deposited at 20 K and that for 80-K films were approximately 2 × 10−6 Torr. Transmittance spectra were obtained for the 500–3700-cm−1 range with a Fourier-transform spectrometer. Values of the optical properties (n, k) for the CO2, H2O, and NH3 cryofilms were derived from the experimental data using a thin-film-transmittance analytical model and the nonlinear least-squares method. Results from the least-squares method are compared with a Kramers–Kronig determination of the refractive index (n). The optical properties (n, k) of such cryofilms are essential for predicting the degradation of contaminated cryocooled optical surfaces.
No takes yet. Share an insight, caveat, or question.
Wood et al. (1982) studied this question.