Key result
A liquid beta(-) radiation (188Re) balloon at 29 Gy reduced histological stenotic area compared to controls in a porcine coronary model.
Why the study?
Does 188Re balloon brachytherapy reduce stent restenosis in a porcine coronary model?
RCT (n=24)
blinded
randomized
Does 188Re balloon brachytherapy reduce stent restenosis in a porcine coronary model?
188Re balloon brachytherapy provides dose-dependent inhibition of stent restenosis in a porcine model, supporting its feasibility for clinical studies.
Answers are grounded in this paper and cite their sources.
Hypothesis-generating in porcine model; leaves open translation to human restenosis trials.
BACKGROUND: Restenosis within stents may be prevented by ionizing radiation from an intravascular source. METHODS AND RESULTS: A liquid beta(-) radiation ((188)Re) balloon was evaluated in a randomized and blinded porcine coronary model of stent restenosis. Group A pigs (n=17) received 0,16, 22, or 29 Gy at 0.5-mm depth, followed by stenting. Restenosis was quantified by angiography, ultrasound, and histomorphometry at 30 days. Group B (n=7) was stented first and then treated with 0 or 29 Gy with follow-up at 60 days. There was a measurable effect at 16 Gy, which improved with increasing doses. At 29 Gy, the histological stenotic area was reduced by 67% (22% versus 66% in controls, P<0.001). Radiation after stenting was equally effective; the stenotic area was reduced (21% versus 65%, P<0.001). At 16 Gy, the vessel just distal to the stent was significantly smaller than control vessels because of intimal thickening (P=0.003). Radiated vessels had distinctive histology consisting of neointimal fibrin and reduced smooth muscle cells and matrix (P<0.0001). CONCLUSIONS: (188)Re balloon brachytherapy in porcine coronary arteries results in dose-dependent and injury-independent inhibition of stent restenosis for up to 60 days. Restenosis at the borders of the irradiated zone is a potential limitation and may be related to underdosing. Brachytherapy with the (188)Re balloon appears to be safe and feasible for clinical studies.
No takes yet. Share an insight, caveat, or question.
Makkar et al. (2000) conducted an RCT in stent restenosis (n=24). liquid beta(-) radiation (188Re) balloon vs. 0 Gy (control) was evaluated on histological stenotic area (p=<0.001). A liquid beta(-) radiation (188Re) balloon at 29 Gy reduced histological stenotic area compared to controls in a porcine coronary model.