Key result
The Quantitative Blush Evaluator (QuBE) score showed no significant association with Myocardial Blush Grade, suggesting it is not suitable for quantitative assessment of myocardial perfusion.
Why the study?
Does the Quantitative Blush Evaluator (QuBE) software accurately assess myocardial perfusion compared to Myocardial Blush Grade (MBG) in STEMI patients after primary PCI?
Observational (n=117)
Blinded evaluation
Yes
Does the Quantitative Blush Evaluator (QuBE) software accurately assess myocardial perfusion compared to Myocardial Blush Grade (MBG) in STEMI patients after primary PCI?
The QuBE software did not show a significant association with visual Myocardial Blush Grade scores, suggesting it may not be suitable for quantitative assessment of myocardial perfusion without further improvements.
Answers are grounded in this paper and cite their sources.
QuBE lacks association with MBG post-primary PCI; leaves open its suitability for quantitative perfusion assessment.
BACKGROUND AND AIM: Quantitative Blush Evaluator (QuBE) is a software application that allows quantifying myocardial perfusion in coronary angiograms after a percutaneous coronary intervention. QuBE has some limitations such as the application of a crude filter to remove large scale structures and the absence of correction for cardiac motion. This study investigates the extent of these limitations and we hypothesize that enhanced image analysis methods can provide improvements. METHODS: We calculated QuBE scores of 117 patients from the HEBE Trial and determined its association with the Myocardial Blush Grade (MBG) score. Accuracy of large-structure removal is qualitatively assessed for various sizes of a median filter. The influence of cardiac motion was evaluated by comparing the blush curve and QuBE score of the native QuBE with manually motion-corrected QuBE for 40 patients. The effect of different kernel sizes and motion correction to a potential improvement of the association between QuBE score and MBG was studied. RESULTS: In our population, there was no significant association between QuBE score and MBG (p = 0.14). Median filters of various kernel sizes were unable to remove large structure related noise. Variations in filters and cardiac movement correction did not result in an improvement in the association with MBG scores (observer 1: p = 0.66; observer 2: p = 0.72). CONCLUSIONS: There was no significant association of QuBE with MBG scores in our population, which suggests that QuBE is not suitable for a quantitative assessment of myocardial perfusion. Alternative kernel sizes for the large structure removal filter and cardiac motion correction did not improve QuBE performance. RELEVANCE FOR PATIENTS: Further improvements of QuBE to overcome its inherent limitations are necessary in order to establish QuBE as a reliable myocardial perfusion assessment method.
No takes yet. Share an insight, caveat, or question.
Prasetya et al. (2018) conducted an observational in ST-segment elevation myocardial infarction (n=117). Quantitative Blush Evaluator (QuBE) vs. Myocardial Blush Grade (MBG) was evaluated on Association between QuBE score and Myocardial Blush Grade (MBG) (p=0.14). The Quantitative Blush Evaluator (QuBE) score showed no significant association with Myocardial Blush Grade, suggesting it is not suitable for quantitative assessment of myocardial perfusion.
Synapse has enriched 10 related papers. Consider them for comparative context: