Key result
Central aortic blood pressure assessed by AI-based pulse wave analysis was significantly lower than conventionally measured peripheral systolic blood pressure (114.3 vs 135.4 mm Hg; p<0.001).
Why the study?
Despite treatment for aortic coarctation, arterial hypertension can develop, but conventional blood pressure measurements lack precision for individual diagnoses and therapeutic decisions.
Does AI-PWA assessment of central aortic blood pressure provide different hypertension diagnostic rates compared to conventional peripheral blood pressure measurement in adults after treatment of aortic coarctation?
Cross-Sectional (n=47)
Does AI-PWA assessment of central aortic blood pressure provide different hypertension diagnostic rates compared to conventional peripheral blood pressure measurement in adults after treatment of aortic coarctation?
Absolute Event Rate: 114.3% vs 135.4%
p-value: p=<0.001
AI-based pulse wave analysis for central aortic blood pressure yields significantly lower systolic values than peripheral measurement in post-treatment aortic coarctation patients, potentially reducing hypertension overdiagnosis.
May aid central BP assessment in CoA; leaves open clinical utility pending prospective validation.
BACKGROUND: Aortic coarctation (CoA) is a congenital anomaly leading to upper-body hypertension and lower-body hypotension. Despite surgical or interventional treatment, arterial hypertension may develop and contribute to morbidity and mortality. Conventional blood pressure (BP) measurement methods lack precision for individual diagnoses and therapeutic decisions. This study evaluated the use of artificial intelligence-based pulse wave analysis (AI-PWA) to assess central aortic blood pressure (CABP) and related parameters in post-treatment CoA patients. METHODS: This exploratory, cross-sectional study enrolled 47 adults with CoA, between June 2023 and May 2024. Peripheral BP (PBP) was conventionally measured, and CABP was assessed using the VascAssist2 (inmediQ, Butzbach, Germany). Hypertension was defined by systolic BP≥140 mm Hg and/or diastolic BP≥90 mm Hg for PBP. Using AI-PWA, patients with systolic CABP≥130 mm Hg and/or diastolic BP≥90 mm Hg were classified as hypertensive. RESULTS: The study cohort's age was 41.5±13.7 years, with all patients having undergone previous aortic surgery or intervention. PBP measurements showed a systolic BP of 135.4±14.4 mm Hg at the upper and 147.8±20.3 mm Hg at the lower extremities. CABP measurements were significantly lower, with a systolic BP of 114.3±15.8 mm Hg (p<0.001). Overall, 32 patients (68.1%) were diagnosed as hypertensive, either by PBP measurement (n=13/27.7%), because of antihypertensive treatment (n=9; 40.4%), or a combination of both. The measurement of PBP was more likely to indicate arterial hypertension than the measurement of CABP (n=12; 25.5% vs n=4; 8.5%). Pulse wave velocity, indicative of aortic stiffness, averaged 9.1 m/s, with higher values in 13 patients (27.7%), including 4 after end-end anastomosis, 2 after graft interposition and 7 after stent placement/angioplasty as the most recent procedure. An increased augmentation index as an indicator of arterial stiffness was observed in nine patients (19.1%). Comparing PBP and CABP in the entire collective, significant differences were found for CABP in relation to the procedure performed, with higher values in patients after prosthesis interposition as their last treatment (p<0.05). CONCLUSION: AI-PWA provides valuable insights into cardiovascular stress in CoA patients, beyond PBP measurements. The study highlights the need to incorporate CABP measurements into clinical practice to avoid overdiagnosis of hypertension. Further research with larger cohorts is needed to validate these findings and refine management strategies for CoA patients.
No takes yet. Share an insight, caveat, or question.
Freilinger et al. (2025) conducted a cross-sectional in Aortic coarctation (CoA) (n=47). Artificial intelligence-based pulse wave analysis (AI-PWA) vs. Conventional peripheral blood pressure (PBP) measurement was evaluated on Systolic blood pressure (p=<0.001). Central aortic blood pressure assessed by AI-based pulse wave analysis was significantly lower than conventionally measured peripheral systolic blood pressure (114.3 vs 135.4 mm Hg; p<0.001).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: