Key result
In patients with low-gradient aortic valve stenosis, catheter-induced postextrasystolic potentiation ≥20% yielded 100% sensitivity and 77% specificity for diagnosing severe stenosis.
Why the study?
Determining which patients with low-gradient aortic valve disease have severe stenosis can be difficult, prompting evaluation of catheter-induced postextrasystolic potentiation.
Does catheter-induced postextrasystolic potentiation accurately diagnose severe stenosis in patients with low-gradient aortic valve stenosis?
Cross-Sectional (n=28)
Does catheter-induced postextrasystolic potentiation accurately diagnose severe stenosis in patients with low-gradient aortic valve stenosis?
Effect estimate: 100% sensitivity, 77% specificity
Catheter-induced postextrasystolic potentiation with a ≥20% increase in mean gradient is a highly sensitive method for diagnosing severe low-gradient aortic valve stenosis during cardiac catheterization.
PESP may aid severe low-gradient AS diagnosis during catheterization; leaves open prospective validation before practice change.
Background: Deciphering which patients with low-gradient aortic valve disease have severe stenosis can be difficult. We aimed to correlate the postextrasystolic potentiation (PESP) with dobutamine stress echocardiography and multidetector computed tomography in patients with low-gradient aortic valve stenosis. Methods: Patients with an aortic valve area ≤1 cm 2 and a mean gradient <40 mm Hg were included. Aortic valve stenosis severity was assessed by a core lab with dobutamine stress echocardiography, followed by a multidetector computed tomography aortic valve score if indeterminate. A premature ventricular contraction was induced by intentional catheter contact with the myocardium within the left ventricle. PESP was calculated as a percent change of pre-to-post mean gradient. Multidetector computed tomography was used to measure the aortic valve calcification score, and subsequently, aortic valve calcification density. Results: Twenty-eight patients (age, 77±10 years; 19 female) were included. Dobutamine stress echocardiography increased mean gradient from baseline of 25±7 mm Hg to 36±11 mm Hg; pre-premature ventricular contraction mean gradient was 25±7 mm Hg and increased to post-premature ventricular contraction mean gradient of 32±10 mm Hg, representing a PESP of 24±11%. A ≥20% in PESP resulted in 100% sensitivity, 77% specificity, 83% positive predictive value, and 100% negative predictive value for diagnosing severe aortic valve stenosis. There was a significant correlation between PESP and projected aortic valve area and aortic valve calcification density (R=−0.64, P =0.0003; R=0.057, P =0.014, respectively). Conclusions: In patients with low-gradient aortic valve stenosis, catheter-induced premature ventricular contractions during cardiac catheterization causing ≥20% PESP has a 100% sensitivity for severe aortic valve stenosis. Validation of this 20% cutoff in larger groups with correlation to clinical end points is required.
No takes yet. Share an insight, caveat, or question.
Dehghani et al. (2023) conducted a cross-sectional in Low-gradient aortic valve stenosis (n=28). Catheter-induced postextrasystolic potentiation (PESP) ≥20% was evaluated on Diagnosing severe aortic valve stenosis (100% sensitivity, 77% specificity). In patients with low-gradient aortic valve stenosis, catheter-induced postextrasystolic potentiation ≥20% yielded 100% sensitivity and 77% specificity for diagnosing severe stenosis.