Key result
In a pig model of acute myocardial infarction, mean arterial pressure declined from 61 to 50 mmHg within 15 minutes, accompanied by early changes in EKG, lactate, and troponin levels.
Why the study?
Early diagnosis of AMI is vital for prognosis but delayed by patient hesitation and lack of timely evaluations, while wearable devices increasingly track clinical indicators.
Can changes in blood pressure, EKG, lactate, and troponin levels be detected early during acute myocardial infarction in a pig model for potential wearable device application?
Can changes in blood pressure, EKG, lactate, and troponin levels be detected early during acute myocardial infarction in a pig model for potential wearable device application?
Key physiological and biomarker indicators change rapidly within minutes of AMI onset in a pig model, highlighting the potential for early detection using wearable devices.
Animal data on wearable variables in early AMI leave human diagnostic utility open; prospective trials needed.
We examined the changes in variables that could be recorded on wearable devices during the early stages of acute myocardial infarction (AMI) in an animal model. Early diagnosis of AMI is important for prognosis; however, delayed diagnosis is common because of patient hesitation and lack of timely evaluations. Wearable devices are becoming increasingly sophisticated in the ability to track indicators. In this study, we retrospectively reviewed the changes in four variables during AMI in a pig model to assess their ability to help predict AMI onset. AMI was created in 33 pigs by 90-min balloon occlusion of the left anterior descending artery. Blood pressure, EKG, and lactate and cardiac troponin I levels were recorded during the occlusion period. Blood pressure declined significantly within 15 min after balloon inflation (mean arterial pressure, from 61 ± 8 to 50 ± 8 mmHg) and remained at this low level. Within 5 min of balloon inflation, the EKG showed ST-elevation in precordial leads V1-V3. Blood lactate levels increased gradually after occlusion and peaked at 60 min (from 1.48 to 2.53 mmol/L). The continuous transdermal troponin sensor demonstrated a gradual increase in troponin levels over time. Our data suggest that significant changes in key indicators (blood pressure, EKG leads V1-V3, and lactate and troponin levels) occurred at the onset of AMI. Monitoring of these variables could be used to develop an algorithm and alert patients early at the onset of AMI with the help of a wearable device.
No takes yet. Share an insight, caveat, or question.
Li et al. (2023) studied acute myocardial infarction (AMI) (n=33). Acute myocardial infarction (AMI) induced by balloon occlusion vs. Baseline was evaluated on Changes in blood pressure, EKG, lactate, and cardiac troponin I levels. In a pig model of acute myocardial infarction, mean arterial pressure declined from 61 to 50 mmHg within 15 minutes, accompanied by early changes in EKG, lactate, and troponin levels.