This is the authors' abstract. We don't add key points for this paper.
The resolving power of a far-field fluorescence microscope is determined by its diffraction limit only when infinite photons are considered. To determine the resolvability of a specimen, photon noise, however, remains one essential factor yet to be considered statistically. We proposed an information-based resolution measure quantifying the theoretical resolving power of a fluorescence microscope in the condition of finite photons. The developed approach allows us to quantify the practical resolution limit of varieties of fluorescence and super-resolution microscopy modalities, and further for microscopy developments, may be used to predict the achievable resolution of a microscopy design at various photon levels. In 1873, Abbe published his work stating that microscopy resolution solely depends on the numerical aperture and wavelength of the light [1,2], a statement later verified theoretically [3,4]. This limit is often sufficient for traditional microscopes where transmission, reflection, or scattered light is collected as signals [5], for which the signal-to-noise ratio can be increased by adjusting the illumination power. However, for fluorescence microscopes, photons—the sole source of molecular information generated by individual fluorescent probes—are limited due to the photobleaching and photochemical environment of the fluorophores [6,7]. Due to the discrete nature of light, the photon counting noise is inherent following Poisson distribution, where the signal-to-noise ratio will decrease with a decreasing number of detected photons. As a result, at low photon levels, it would be difficult to determine whether the captured intensity differences are from underlying structure or noise fluctuations, thus preventing microscopy methods from achieving their theoretical resolution limit [8-12]. Here, we propose a quantitative and theoretical measure of the resolving power of microscopes considering numerical aperture, emission wavelength, and photon statistics. Specifically, we consider the grating’s phase estimation precision as a measure of the resolving power of the imaging system. Based on an adjustable criterion of the achievable precision lower bound, we defined the information-based resolution (IbR) and used it in evaluating and distinguishing the significant resolving power differences among various conventional and super-resolution imaging modalities including wide-field microscopy, confocal microscopy [13,14], structured illumination microscopy (SIM) [15,16], and image scanning microscopy (ISM) [17-19]. We expect IbR to be a useful measure in estimating the noise-considered resolution to guide and validate the design of newly developed or proposed imaging modalities. Visualization of noise influence on the resolvability of a single-tone sinusoidal wave grating object. The resolvability in terms of σϕ is considered the resolving power of this wide-field system. Noisy images are simulated with different intensities in this wide-field system. The frequency of the object is 1.6NAλ. Figures from left to right each has photon density of 500 photons/μm2, 5000 photons/μm2, and 50,000 photons/μm2. Comparison of four imaging modalities, wide-field microscopy, confocal microscopy, SIM, and ISM at resolving different frequencies using phase estimation precision limit σϕ. (a) Resolving power in terms of σϕ demonstrated for four imaging modalities. The lateral black dashed line (σϕ=0.04rad) indicates the applied resolving criterion. Colored dashed lines indicate the reciprocal of IbR for each imaging modality. (b) Visualization of noisy images for an object of frequency 2.1NAλ, a frequency slightly higher than the diffraction limit. (c) Photons per area required for different grating structures to reach the applied resolving criterion (σϕ=0.04rad), ranging from 0 to 1 billion photons per μm2. (d) Relationship between σϕ and photon count for an object of frequency 1.85NAλ plotted in log scale.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Li et al. (2023) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: