Key result
Interobserver reliability between a nurse and an anaesthetist for predicting difficult intubation was good or very good for most tests, but moderate for mouth opening and poor for oropharyngeal view.
Why the study?
What is the interobserver reliability between an anaesthetic nurse and a specialist registrar anaesthetist for tests used to predict difficult tracheal intubation?
Observational
What is the interobserver reliability between an anaesthetic nurse and a specialist registrar anaesthetist for tests used to predict difficult tracheal intubation?
Interobserver reliability between a nurse and an anaesthetist for predicting difficult intubation is similar to that between two anaesthetists, with most tests showing good reliability.
Answers are grounded in this paper and cite their sources.
May support nurse-led airway screening in select settings; leaves open whether agreement improves intubation outcomes.
We examined the interobserver reliability, between a nurse and anaesthetist, of five tests used to predict difficult tracheal intubation: mouth opening; thyromental distance; head and neck movement; mandibular luxation; and assessment of oropharyngeal view. For each test, an anaesthetic nurse and a specialist registrar anaesthetist were trained to use a standard method of examination. Most of the tests had either good or very good reliability. Assessment of mouth opening demonstrated only moderate reliability and assessment of oropharyngeal view demonstrated poor reliability. The interobserver reliability estimates between a nurse and an anaesthetist are similar to those previously demonstrated between two anaesthetists.
No takes yet. Share an insight, caveat, or question.
Hilditch et al. (2004) conducted an observational in Difficult tracheal intubation. Tests for predicting difficult tracheal intubation was evaluated on Interobserver reliability. Interobserver reliability between a nurse and an anaesthetist for predicting difficult intubation was good or very good for most tests, but moderate for mouth opening and poor for oropharyngeal view.
Synapse has enriched 10 related papers. Consider them for comparative context: