Key result
Mechanical ventilation with 50% nitrous oxide in oxygen hastened absorptive lung collapse, reaching an airway pressure of -1.0 kPa in a shorter time than 100% oxygen in sheep.
Why the study?
Does mechanical ventilation with 50% nitrous oxide in oxygen speed absorptive lung collapse compared to 100% oxygen in anaesthetised sheep?
Does mechanical ventilation with 50% nitrous oxide in oxygen speed absorptive lung collapse compared to 100% oxygen in anaesthetised sheep?
The use of 50% nitrous oxide in oxygen during mechanical ventilation hastens absorptive lung collapse in a sheep model, which may facilitate thoracoscopic surgery.
Answers are grounded in this paper and cite their sources.
Accelerates absorptive collapse during ventilation in sheep; extends animal observations but leaves open human thoracoscopic applicability.
By enhancing gaseous uptake from the non-ventilated lung during procedures performed thoracoscopically, the rapid diffusion properties of nitrous oxide would be expected to speed lung collapse and so facilitate surgery. To assess the effect of nitrous oxide on the speed of absorptive lung collapse, a study was conducted using 11 anaesthetised sheep. Speed of collapse was assessed in an indirect manner by recording the time required in a closed-chest situation for the airway pressure distal to a single lung airway occlusion to decrease to - 1.0 kPa. The influence of nitrous oxide was assessed by comparing the time taken for this decrease in airway pressure when the animal was being mechanically ventilated with 50% nitrous oxide in oxygen with the time taken when using 100% oxygen. In all assessments, it was found that the decrease in airway pressure to - 1.0 kPa occurred in a shorter time when nitrous oxide was used. The findings lend support to the hypothesis that during thoracoscopic surgery, mechanical lung ventilation with an oxygen/nitrous oxide mixture will increase the rate of gaseous uptake from the non-ventilated lung and so hasten its absorptive collapse.
No takes yet. Share an insight, caveat, or question.
Pfitzner et al. (2001) studied one-lung anaesthesia (n=11). 50% nitrous oxide in oxygen vs. 100% oxygen was evaluated on time required for airway pressure distal to a single lung airway occlusion to decrease to - 1.0 kPa. Mechanical ventilation with 50% nitrous oxide in oxygen hastened absorptive lung collapse, reaching an airway pressure of -1.0 kPa in a shorter time than 100% oxygen in sheep.