Answers are grounded in this paper and cite their sources.
Although many Pb2+-selective optodes have been developed so far, methods using optical sensor membranes have not become widespread in environmental analytical practice. In order to create a bulk optode sensor, which can overcome all of the main drawbacks in the application of conventional optode membranes, - i.e., pH-dependence, long response time and the leakage of the ionic components - unusually thick PVC membrane was developed, embedded in microtiter plates and operated on a novel concept. This is the first reported work, which applies a plate-format optode as well as a direct optode-type sensing membrane for determination of Pb2+. We reported here also the first example for the application of an ionic component-free bulk optode membrane to avoid the membrane leakage, improve the regenerability and extend the lifetime of the membrane. The reported sensor has a LOD above 4.0 × 10−7 M (∼83 μg L−1), thus it is unsuitable for the effective monitoring of drinking waters, but considered to be a promising method for monitoring contamination episodes. On the other hand, the widest pH-independent working range of 4.3 < pH < 7.0 among bulk optodes reported in the literature was realized and an unprecedentedly fast response time of <10 s was achieved. The effectiveness of the applied method was investigated by measuring Pb2+-spiked multicomponent aqueous solutions as simulated environmental or wastewater samples containing near equimolar amounts of Ag+, Ca2+, Co2+, Cu2+, K+, Mg2+, Na+ and Zn2+ as acetate salts. In the presence of these potential competing ions with a concentration not greater than the typical ionic strength of surface freshwaters (∼10−3 M) the reported sensor proved to be appropriate for the selective detection of Pb2+ without any preparation of the samples (e.g., preconcentration, buffering, addition of excipients, etc.) with a required sample volume of only 100 μL. An outstanding analytical performance could be achieved within an average time of less, than 5 s/sample. The reported fluorescent probe is considered to be a promising method for replacing atomic absorption spectroscopy- (AAS), anodic stripping voltammetry- (ASV) or inductively coupled plasma- (ICP) based techniques as well as conventional ion-selective bulk membranes in high-throughput preliminary environmental monitoring of Pb2+, as it provides a cheap and unprecedentedly fast qualitative analysis of contaminated surface and wastewaters.
No takes yet. Share an insight, caveat, or question.
Golcs et al. (2021) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: