Answers are grounded in this paper and cite their sources.
To accurately attribute sources and sinks of molecules like CO₂, remote sensing missions require line intensities (S) with relative uncertainties uᵣ(S)<0.1%. However, discrepancies in S of ≈1% are common when comparing different experiments, thus limiting their potential impact. Here we report a cavity ring-down spectroscopy multi-instrument comparison which revealed that the hardware used to digitize analog ring-down signals caused variability in spectral integrals which yield S. Our refined approach improved measurement accuracy 25-fold, resulting in uᵣ(S)=0.06%.
No takes yet. Share an insight, caveat, or question.
Fleisher et al. (2019) studied this question.