This is the authors' abstract. We don't add key points for this paper.
A piezoelectric-driven actuator based on coupling motion has been proposed and tested to achieve a large linear working stroke with high resolution. “Z-shaped” flexure hinges are exploited for the symmetric flexure hinge mechanism to reduce the structural stress. Coupling motion is obtained by placing this symmetric flexure hinge mechanism with an angle of θ = 20° to the slider. Experimental results indicate that linear motion with a large working stroke is effectively obtained by this coupling motion; the maximum motion speed is Vs= 6057 μm/s and the maximum output force is Fg= 350 g. Additionally, the influences of input frequency f and input voltage Ueare investigated, and the system kinetic model is established to better analyze the performance of this designed piezoelectric-driven linear actuator.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Li et al. (2017) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: