Key result
Post-PCI 3D-QCA-derived vFFR accurately detects invasive microcatheter FFR below 0.90 with ~0.98 AUC.
Why the study?
Does 3D-QCA derived vessel-FFR (vFFR) accurately correlate with and identify invasive microcatheter-based post-PCI FFR <0.90 in patients undergoing coronary stenting?
Cohort (n=100)
Blinded
No
Does 3D-QCA derived vessel-FFR (vFFR) accurately correlate with and identify invasive microcatheter-based post-PCI FFR <0.90 in patients undergoing coronary stenting?
Answers are grounded in this paper and cite their sources.
3D-QCA derived post-PCI vFFR provides a rapid, accurate, and reproducible physiological assessment after coronary stenting without requiring an invasive pressure wire or hyperemic agent.
OBJECTIVES: To validate novel dedicated 3D-QCA based on the software to calculate post PCI vessel-FFR (vFFR) in a consecutive series of patients, to assess the diagnostic accuracy, and to assess inter-observer variability. BACKGROUND: Low post percutaneous coronary intervention (PCI) fractional flow reserve (FFR) predicts future adverse cardiac events. However, FFR assessment requires the insertion of a pressure wire in combination with the use of a hyperemic agent. METHODS: FAST POST study is an observational, retrospective, single-center cohort study. One hundred patients presenting with stable angina or non ST-elevation myocardial infarction, who underwent post PCI FFR assessment using a dedicated microcatheter were included. Two orthogonal angiographic projections were acquired to create a 3D reconstruction of the coronary artery using the CAAS workstation 8.0. vFFR was subsequently calculated using the aortic root pressure. RESULTS: Mean age was 65±12 years and 70% were male. Mean microcatheter based FFR and vFFR were 0.91±0.07 and 0.91±0.06, respectively. A good linear correlation was found between FFR and vFFR (r = 0.88; p <.001). vFFR had a higher accuracy in the identification of patients with FFR values <0.90, AUC 0.98 (95% CI: 0.96-1.00) as compared with 3D-QCA AUC 0.62 (95% CI: 0.94-0.74). Assessment of vFFR had a low inter-observer variability (r = 0.95; p <.001). CONCLUSION: 3D-QCA derived post PCI vFFR correlates well with invasively measured microcatheter based FFR and has a high diagnostic accuracy to detect FFR <0.90 with low inter-observer variability.
No takes yet. Share an insight, caveat, or question.
Masdjedi et al. (2020) conducted a cohort in Stable or unstable angina or non-ST-elevation myocardial infarction undergoing percutaneous coronary intervention (n=100). 3D-QCA based post-PCI vessel fractional flow reserve (vFFR) using CAAS workstation 8.0 vs. Invasively measured microcatheter-based post-PCI FFR (Acist Navvus) and 3D-QCA diameter stenosis was evaluated on Diagnostic accuracy (AUC) to identify post-PCI microcatheter-based FFR <0.90 and correlation between vFFR and invasive FFR (AUC 0.98 (correlation r = 0.88), 95% CI 0.96-1.00, p=<0.001). 3D-QCA derived post-PCI vFFR correlated strongly with invasive microcatheter FFR and showed high accuracy for detecting FFR <0.90.
Synapse has enriched 10 related papers. Consider them for comparative context: