Answers are grounded in this paper and cite their sources.
In cases of displaced greater tuberosity fractures, treatments by arthroscopic-assisted reduction and percutaneous screw fixation have been reported. However, in cases in which there is a comminuted fracture or a minimally displaced fracture combined with concomitant lesions such as rotator cuff tear or labral pathology, it is difficult to reduce the fracture and to treat other pathologies by use of a percutaneous screw. Recently, many surgeons have used the double-row repair method in rotator cuff repair, which provides a tendon-bone interface better suited for biologic healing and restoring normal anatomy. In accordance with this method, we used the arthroscopic technique of double-row suture anchor fixation for a minimally displaced greater tuberosity fracture without additional incision. Initially, debridement was performed on the fracture surface by use of a shaver, and the medial-row anchor was inserted through the anterior portal or the intact cuff. Two lateral-row anchors were inserted just anterior and posterior to the lower margin of the fractured fragment under C-arm guidance. The medial-row sutures and lateral-row sutures were then placed. Arthroscopic double-row suture anchor fixation of a displaced greater tuberosity fracture restores the original footprint of the rotator cuff and normal tendon-bone interface of the displaced greater tuberosity fracture.
No takes yet. Share an insight, caveat, or question.
Ji et al. (2007) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: