Why the study?
LA and LAA dysfunction contribute to AF-related stroke, but the diagnostic usefulness of LA versus LAA mechanics for stroke risk stratification had not been fully compared.
Are left atrial and left atrial appendage mechanical dispersions associated with prior stroke or TIA in patients with nonvalvular atrial fibrillation?
Are left atrial and left atrial appendage mechanical dispersions associated with prior stroke or TIA in patients with nonvalvular atrial fibrillation?
Higher left atrial and left atrial appendage mechanical dispersion measured by speckle-tracking echocardiography are independently associated with a history of stroke or TIA in patients with atrial fibrillation, providing incremental risk stratification value.
Answers are grounded in this paper and cite their sources.
May support incremental AF risk stratification; hypothesis-generating and requires prospective validation before practice change.
BACKGROUND: Left atrial (LA) and left atrial appendage (LAA) dysfunction has been demonstrated to contribute to atrial fibrillation (AF)-related stroke. However, usefulness of LA and LAA mechanics has not been fully compared. We sought to investigate the association of LA and LAA mechanics with stroke and to compare their diagnostic values in the risk stratification of stroke in patients with nonvalvular AF. METHODS: A total of 208 consecutive patients with AF (63.58 ± 10.37 years, 63.9% male,57.7% persistent AF) who underwent echocardiography before catheter ablation were prospectively enrolled. Speckle-tracking was used to measure LA and LAA global longitudinal strain (GLS). LA and LAA mechanical dispersions (MD) were defined as the standard deviation (SD) of time to peak positive strain corrected by the R-R interval. RESULTS: Patients with prior stroke/ transient ischemic attack (TIA) (n = 31) had significantly higher LA and LAA MD than those without (n = 177) (11.56 ± 4.38% vs. 8.43 ± 3.44%, 15.15 ± 5.46% vs. 10.94 ± 4.40%, both P < 0.01). In multivariable analysis, LA and LAA MD were independently associated with stroke/TIA (odds ratio, 1.18-1.29, 1.19-1.22, respectively, both P < 0.01), providing incremental values over clinical and standard echocardiographic parameters. In a subgroup analysis, LA MD was more useful than LAA MD in patients with normal LA volumes, while LAA MD was superior to LA MD in patients with LA enlargement. CONCLUSIONS: Higher LA and LAA mechanical dispersion are independently associated with stroke/TIA in AF patients and had incremental values over clinical and conventional echocardiographic parameters. What's more, priorities of dispersion assessment are different depending on patients' LA size.
No takes yet. Share an insight, caveat, or question.
Mao et al. (2021) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: