Key result
External Teflon ring annuloplasty for aortic regurgitation yields ~97% 8-year survival in cohort study.
Why the study?
Aortic valve repair procedures for aortic regurgitation have been progressively adopted over recent decades, prompting this evaluation of outcomes following external Teflon ring annuloplasty and leaflet repair.
What are the mid-term survival, durability, and predictors of failure of aortic valve repair using an external Teflon ring annuloplasty in patients with aortic valve regurgitation?
Cohort (n=61)
No
What are the mid-term survival, durability, and predictors of failure of aortic valve repair using an external Teflon ring annuloplasty in patients with aortic valve regurgitation?
External Teflon ring annuloplasty for aortic regurgitation provides high mid-term survival and low valve-related complications, with durability significantly improved by objective caliper-guided cusp repair and hindered by severe preoperative annular dilation (≥28 mm).
Answers are grounded in this paper and cite their sources.
Supports caliper-guided aortic repair durability; observational data leaves open need for randomized confirmation before practice change.
OBJECTIVES: Aortic valve repair procedures for aortic valve regurgitation have been progressively adopted in the last decades. We analysed our results with an external ring annuloplasty and/or leaflet repair. METHODS: From April 2014 to December 2023, 61 consecutive patients underwent aortic valve repair with external Teflon ring annuloplasty. The external ring was made of an 8-9 mm Teflon strip, to reduce the annulus diameter between 21 and 23 mm. Cusp effective height (eH) was assessed with a caliper (not used before 2018), and any cusp prolapse was corrected by free margin plication, to obtain a 9-10 mm eH for all cusps. RESULTS: Patients (72.1%) had severe aortic regurgitation (AR), and associated supracoronary aneurysm repair was performed in 42.6%. No operative death occurred; residual AR more-than-moderate was present in one patient only. The 8-year overall survival was 97.4 ± 2.6%, freedom from endocarditis 98.3 ± 1.7% and freedom from thromboembolism 100%. Recurrence of severe AR with need for reoperation was predicted by the presence of a particularly enlarged aortic annulus (≥28 mm, P < 0.01) and the non-routinary use of cusp caliper (P = 0.03). CONCLUSIONS: The external Teflon ring annuloplasty appears a safe procedure with high overall survival, freedom from endocarditis and freedom from thromboembolism at 10 years. Recurrence of severe AR could be related to patient selection and learning curve.
No takes yet. Share an insight, caveat, or question.
Irace et al. (2025) conducted a cohort in Aortic valve regurgitation (predominantly bicuspid aortic valve, 90.1%) (n=61). Aortic valve repair with external Teflon ring annuloplasty and/or cusp free margin plication vs. Subgroup comparisons: caliper-guided vs eyeballing cusp assessment; baseline annulus diameter ≥28 mm vs <28 mm was evaluated on 8-year overall survival. External Teflon ring annuloplasty for aortic regurgitation achieved 97.4% 8-year survival and 80.3% freedom from reoperation, with caliper use reducing reoperation.
Synapse has enriched 10 related papers. Consider them for comparative context: