Key result
Aortic valve leaflet replacement with bovine pericardium resulted in flexible leaflet movement, no regurgitation, and preserved annulus dynamics at 5.5 years in a patient with a small annulus.
Why the study?
Does aortic valve leaflet replacement with bovine pericardium preserve native dynamic capabilities of the aortic annulus in a patient with a bicuspid and stenotic aortic valve?
Case Report (n=1)
Does aortic valve leaflet replacement with bovine pericardium preserve native dynamic capabilities of the aortic annulus in a patient with a bicuspid and stenotic aortic valve?
Aortic valve leaflet replacement with bovine pericardium may preserve the dynamic capabilities of the native aortic annulus and serve as an alternative to standard valve replacement for aortic stenosis.
Valve replacement is typically the most appropriate option for treating aortic valve stenotic insufficiency. However, neither mechanical nor bioprosthetic replacement components preserve the circumferential expansion and contraction of a native aortic annulus during the cardiac cycle, because the prosthetic ring is affixed to the annulus. A 64-year-old man presented with a bicuspid and stenotic aortic valve, and the native annulus was too small to accommodate a porcine replacement valve. We fashioned new aortic leaflets from bovine pericardium with use of a template, and we affixed the sinotubular junction with use of inner and outer stabilization rings. Postoperative echocardiograms revealed coaptation of the 3 new leaflets with no regurgitation. At the patient's 5.5-year follow-up examination, echocardiograms showed flexible leaflet movement with a coaptation height of 7 mm, and expansion and contraction of the aortic annulus similar to that of a normal native annulus. The transvalvular pressure gradient was insignificant. If long-term durability of the new leaflets is confirmed, this method of leaflet replacement and fixation of the sinotubular junction might serve as an acceptable alternative to valve replacement in the treatment of aortic valve stenosis. We describe the patient's case and present our methods and observations.
No takes yet. Share an insight, caveat, or question.
Kim et al. (2014) conducted a case report in Aortic valve stenosis (n=1). Aortic valve leaflet replacement with bovine pericardium was evaluated on Echocardiographic findings (coaptation, regurgitation, leaflet movement, transvalvular pressure gradient). Aortic valve leaflet replacement with bovine pericardium resulted in flexible leaflet movement, no regurgitation, and preserved annulus dynamics at 5.5 years in a patient with a small annulus.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: