Key result
Omitting cardiac implantable electronic device extraction in patients with monomicrobial Enterococcus faecalis bacteremia resulted in a 10% recurrence rate compared to 0% in extracted patients, suggesting extraction may be safely omitted if no structural changes are found.
Why the study?
Guidelines recommend CIED extraction when CIED infection or IE is diagnosed, but whether extraction should be performed in other situations with Enterococcus faecalis bacteremia is unknown.
Does CIED extraction prevent recurrent infection in patients with CIED and monomicrobial Enterococcus faecalis bacteremia?
Cohort (n=72)
Does CIED extraction prevent recurrent infection in patients with CIED and monomicrobial Enterococcus faecalis bacteremia?
Answers are grounded in this paper and cite their sources.
In patients with monomicrobial Enterococcus faecalis bacteremia and a CIED, omitting device extraction appears safe if no structural changes are found on the device.
PURPOSE: In all patients with cardiac implantable electronic devices (CIED) and Enterococcus faecalis bacteremia (EfsB), endocarditis (IE) and CIED infection should be suspected. Guidelines recommend extraction of the CIED when CIED infection or IE is diagnosed. Whether extraction of the CIED should be done in other situations with EfsB is not known. We aimed to describe the management and outcome of patients with CIED and monomicrobial EfsB, in relation to extraction and recurrent EfsB. METHODS: A population-based cohort of patients with monomicrobial EfsB from January 2014 to November 2020 was identified through microbiology registers in the Region Skåne, Sweden. Data on CIED and other clinical features were collected from medical records. RESULTS: Among 1087 episodes of EfsB, 72 patients with CIED and monomicrobial EfsB were identified. Five of these patients were diagnosed with IE (7%), three of whom had echocardiographic changes on the CIED. Four CIED were extracted (6%). Recurrences were found in seven of 68 patients (10%) not subjected to extraction and in none of the extracted. In the group of patients without extraction, community acquisition and predisposition for IE were significantly associated with recurrent infection in univariate analyses. No infections involving the CIED were diagnosed during the recurrences. CONCLUSIONS: In patient with monomicrobial EfsB, it seems safe to omit extraction if no structural changes are found on the CIED.
No takes yet. Share an insight, caveat, or question.
Berge et al. (2022) conducted a cohort in Enterococcus faecalis bacteremia in patients with cardiac implantable electronic devices (n=72). CIED extraction vs. No CIED extraction was evaluated on Recurrent infection with Enterococcus faecalis bacteremia during the 365-day observation period. Omitting cardiac implantable electronic device extraction in patients with monomicrobial Enterococcus faecalis bacteremia resulted in a 10% recurrence rate compared to 0% in extracted patients, suggesting extraction may be safely omitted if no structural changes are found.