Key result
Tricuspid valve repair using fresh autologous pericardium and synthetic chordae successfully treated right-sided infective endocarditis with no recurrence of infection or regurgitation at 1 year.
Why the study?
Right-sided infective endocarditis is uncommon, and cases secondary to ventricular septal defect are rarely encountered in clinical practice.
Case Report (n=1)
No
Tricuspid valve repair using fresh autologous pericardium and an annuloplasty ring was successfully performed in a patient with right-sided infective endocarditis secondary to VSD, with good 1-year outcomes.
Answers are grounded in this paper and cite their sources.
May support autologous pericardial repair in select right-sided IE cases; leaves open need for larger studies on durability.
No abstract yet. The journal hasn't published one we can show.
No takes yet. Share an insight, caveat, or question.
Ogawa et al. (2019) conducted a case report in Right-sided infective endocarditis with ventricular septal defect and severe tricuspid regurgitation (n=1). Tricuspid valve repair with fresh autologous pericardium and synthetic chordae was evaluated on Recurrence of infection and tricuspid valve regurgitation. Tricuspid valve repair using fresh autologous pericardium and synthetic chordae successfully treated right-sided infective endocarditis with no recurrence of infection or regurgitation at 1 year.