Key result
Tricuspid valve replacement using a handmade single tube of CorMatrix Extracellular Matrix was safe and resulted in symptomatic resolution and normal valve function in early follow-up.
Case Report (n=1)
Tricuspid valve replacement using a handmade single tube of CorMatrix Extracellular Matrix is a feasible surgical option for active endocarditis with extensive valve destruction.
Answers are grounded in this paper and cite their sources.
Single-case report supports CorMatrix tube feasibility in tricuspid endocarditis; leaves open durability and generalizability.
Tricuspid valve replace in patients with active endocarditis can be a challenging decision in surgical options. In this experience, we replaced the tricuspid valve using a handmade single tube of CorMatrix Extracellular Matrix (ECM) (CorMatrix Cardiovascular Inc, Roswell, Ga). Its showed to be safe and useful in a young patient with extensive valve destruction and early follow-up showed symptomatic resolution and valve normal function.
No takes yet. Share an insight, caveat, or question.
Lucero et al. (2018) conducted a case report in Active endocarditis with extensive valve destruction (n=1). Tricuspid valve replacement using a handmade single tube of CorMatrix Extracellular Matrix (ECM) was evaluated on Symptomatic resolution and valve normal function. Tricuspid valve replacement using a handmade single tube of CorMatrix Extracellular Matrix was safe and resulted in symptomatic resolution and normal valve function in early follow-up.