Key result
Implantation of a pericardial cylinder in the tricuspid position resulted in no recurrence of infective endocarditis within the cylinder, although 3 of 7 patients developed cylinder degeneration.
Why the study?
It was hypothesized that total elimination of artificial material and implantation of entirely patient-derived biological material would reduce infective endocarditis recurrence in tricuspid valve endocarditis.
Observational (n=7)
No
Pericardial cylinder implantation for tricuspid valve infective endocarditis prevents local recurrence but is limited by early valve degeneration and stenosis in a significant proportion of patients.
Answers are grounded in this paper and cite their sources.
Autologous pericardial valves should not yet change tricuspid IE practice; leaves open recurrence reduction versus prostheses in larger trials.
Introduction: Infective endocarditis (IE) on the tricuspid valve usually requires the complete resection of the infected tissue and implantation of a valve prosthesis. Aim: We assumed that total elimination of artificial material and implantation of the entirely patient-derived biological material would reduce the recurrence of IE. Material and methods: The group consisted of 7 consecutive patients who underwent implantation of a cylindrical valve created from the patient's own pericardium in the tricuspid orifice. There were only men aged 43 to 73 years. Isolated tricuspid valve reimplantation with a pericardial cylinder was performed in 2 patients. Five (71%) patients needed additional procedures. The postoperative follow-up ranged from 2 to 32 months (median: 17 months). Results: In patients who underwent isolated tissue cylinder implantation, the average extracorporeal circulation (ECC) time was 77.5 minutes and aortic cross-clamp time was 58 minutes. In cases where additional procedures were performed the ECC and X-clamp times were 197.4 and 156.2 minutes, respectively. The function of the implanted valve was examined after weaning from the ECC by transesophageal echocardiogram, followed by transthoracic echocardiogram on day 5-7 after surgery revealed normal function of the prosthesis in all patients. There was no operative mortality. Two late deaths were observed. Conclusions: In the follow-up period none of the patients had a recurrence of IE within the pericardial cylinder. Degeneration with subsequent stenosis of the pericardial cylinder occurred in 3 patients. One patient was reoperated on; one had a transcatheter valve-in-valve cylinder implantation.
No takes yet. Share an insight, caveat, or question.
Charkiewicz-Szeremeta et al. (2023) conducted an observational in Infective endocarditis of the tricuspid valve (n=7). Pericardial cylinder implantation was evaluated on Recurrence of infective endocarditis within the pericardial cylinder. Implantation of a pericardial cylinder in the tricuspid position resulted in no recurrence of infective endocarditis within the cylinder, although 3 of 7 patients developed cylinder degeneration.
Synapse has enriched 10 related papers. Consider them for comparative context: