Answers are grounded in this paper and cite their sources.
A fault section detection system that uses optical magnetic field sensors and instantly detects the section in which a ground fault occurred was developed for 66 kV underground multiterminal systems having Y-branch joint boxes. The optical magnetic field sensor, which is based on the Faraday effect in Bi-doped YIG ((BiYbGd)/sub 3/Fe/sub 5/O/sub 12/) having a large Verdet constant, detects cable conductor currents of 0 to 2000 A with high precision with the use of a laminated magnetic ring core of silicon steel plates. Sensors and a fault section detector/indicator of a system are connected with optical fibers capable of nonrepeated transmission of over 6 km.>
No takes yet. Share an insight, caveat, or question.
Katsuta et al. (1992) studied this question.